Unique Products for Gas Distribution

Unique Products for Gas Distribution

STS Skinner Stop-Off Tool

SKINNER SAFE-T-STOPPER KIT (PDF)

Stop off Skinner tees and plug the main through a ball valve, with everything the crew needs in one case.
skinner tee plug

#54-75020SKINR

SKINNER SAFE-T-STOPPER KIT

SKINNER CASE

Operation Video

How it Works

  1. Mount the Thread Adapter and Ball Valve on the tee.
thread adapter and ball valve

2. Remove the Skinner Screw from the tee with the Skinner Tool and jaws.

Skinner Jaws Removal Guide

3. Install the Self Tap Plug through the valve with the Stopping Tool. Bleed off and confirm a full stop at the meter.

PPE Worker Operating Stopping Tool

4. Now the tee can be abandoned according to your company procedures.

skinner abandoned2